在線式不斷電系統
先鋒系列 UPS
Vanguard 6000/8000/10000
 

 


VGD-6K-8K-10K-LCD
Front View | Back View
Back View


Multi Functional LCD On-Line UPS.

15 LCD Display:
Easy viewing of UPS status from LCD panel including:

O/P Voltage O/P Load (%) Battery Charge (%)
O/P Frequency O/P Watt (W) Temperature (°C)
I/P Voltage O/P VA Battery Pack Number
I/P Frequency O/P Current (A) Rating (A)
Battery Voltage Back Up Time (Min.) CPU Version

14 UPS parameter settings:
O/P Voltage O/P Load (%) Battery Charge (%)
O/P Frequency O/P Watt (W) Temperature (°C)
I/P Voltage O/P VA Battery Pack Number
I/P Frequency O/P Current (A) Rating (A)
Battery Voltage Back Up Time (Min.) CPU Version


Unique Design :
- Vanguard rack mount models come in different heights such as 1U, 2U, or 3U to meet different space demands.
- Vanguard rack mount now is available from 700VA up to 12KVA
- Vanguard 3U rack mount model is designed to be flexible and able to fit in different spaces.
- The control panel can be adjusted 90 degree around to accommodate the UPS installation direction (vertically or horizontally)
- The display panel can be remove from the front panel and attached to the back panel with a cable in order to provide the wired-remote feature.
- 2 different directions of insertion slots are designed to attached with display panel providing 2 different angels to suit in different space demands.


FEATURES:

  • Cold start function (DC power on)
  • Lightning and surge protection
  • Battery replacement warning
  • Schedule shutdown & reboot
  • Hot swappable battery by user
  • Emergency Power Off function
  • Battery remain time display
  • LCD display front panel
  • Optional SNMP Card slot
  • Wide input voltage range
  • Power factor correction
  • Manual bypass setting
  • Free run mode setting
  • EMI/RFI noise filter
  • Support USB communication
  • Multiple language LCD display
  • On line output voltage selected


     

  • True on-line technology provides all power protection
  • Pure sine-wave output with less than 3% THD
  • Fully digitized microprocessor controlled
  • Short Circuit and overload protection
  • Advanced battery management (ABM)
  • Automatic battery charge in UPS off mode
  • Automatic diagnostics & battery check
  • RS-232 communication port with monitoring software
  • Network/fax/modem surge protection
  • History record of power failure events
  • UPSMON plus software monitoring
  • Extended back up time with battery pack
  • Optional Extension battery pack
  • Load segmentation receptacles controllable
  • High efficiency mode selectable
  • Fan speed auto control when loads varies

Tower Model (With LCD Display) VGD-6000 VGD-8000 VGD-10000
INPUT Capacity (VA) 6000VA 8000VA 10000VA
Capacity (W) 4200W 5600W 7000W
Voltage

208V/220V/230V/240V

Voltage / Range

Load Capacity

Voltage / Range

Load Capacity

120 ~ 139V

0 ~ 25%

180 ~ 276V

0~100%

140 ~ 159V

0 ~ 50%

160 ~ 179V

0 ~ 75%

Frequency 50 / 60 Hz Auto Sensing
OUTPUT Voltage (on battery) 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage)
Frequency (on battery) 50 / 60 Hz +/-0.5%
Transfer Time 0 ms
Overload Recovery Auto transfer to UPS
High Efficiency Mode (AC to AC) > 97 % > 97%
UPS Design Technology On-Line / Fully digitized microprocessor controlled
Output Wave Form Sinewave
Harmonic Distortion < 3% of T.H.D. at linear load
Crest Factor 3 : 1
PROTECTION & FILTERING Surge Protection IEEEC61000-4-5 Level 3
Overload Protection

125% for 1 minute and 150% for 10 seconds(On-line)

130% for 10 seconds and 150% for 1.5 seconds(On-battery)

Short Circuit Protection UPS output cut off immediately or input fuse / circuit breakerprotection
SYSTEM
DISPLAY / WARNING
Visual Display (LED Model) UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)
Visual Display (LCD Model) Input / output voltage, input / output frequency, on-line mode, back up mode, battery capacity, load level
Audible Alarm (Battery Back-Up) Beep every 5 sec
UPS Fault Continuous beeping sound and LCD display
Communication RS-232 Serial Port and USB
BATTERY Type Sealed, maintenance-free lead acid batteries
DC Voltage (V) Battery (Tower ) 240V / 12V7AH
x 20
240V / 12V7AH
x 20
240V / 12V9AH
x 20
Typical Recharge Time to 90% Full 4 hours
Management Self-test, adjustable battery transfer points and alarm settings
Battery Protection Cut off without draining any current when battery is low
Cold Start (DC Start) YES
Back Up Time (Tower Model) 4~7 mins Full load
10~18 mins Half Load
4~7 mins Full load
10~18 mins Half Load
PHYSICAL Input lnlet Hardwire
Receptacles Hardwire
Tower Dimensions
W/O ISO
mm (inch) WxDxH
257 x 590 x 570
(10.1"x23.2"x22.4")
257 x 690 x 715
(10.1"x27.2"x28.1")
257 x 690 x 715
(10.1"x27.2"x28.1")
Net Weight kg (lb)
Tower w/o ISO
86.0 Kg (189.2) 112 Kg (246.4) 112 Kg (246.4)
Shipping Weight kg (lb)
Tower w/o ISO
106.0 Kg (233.2) 139.0 Kg (305.8) 139.0 Kg (305.8)
Tower Dimensions
With ISO
mm (inch) WxDxH
257 x 590 x 700
(10.1"x23.2"x27.6")
342 x 690 x 715
(13.4"x27.1"x28.1")
342 x 690 x 715
(13.4"x27.1"x28.1")
Net Weight kg (lb)
Tower with ISO
123 Kg (270.6) 178 Kg (391.6) 178 Kg (392.1)
Shipping Weight
Tower with ISO
145 Kg (319) 210 Kg (462) 210 Kg (462.6)
ENVIRONMENT Operating Temperature 0 - 40 deg C / 32 ~ 104 deg F
Storage Temperature -20 ~ 50 deg C / -4 ~ 122 deg F
Audible Noise
(1 meter from surface)
< 55 dBA
Relative Humidity 0 ~ 95% humidity, non-condensing
CONFORMANCE Safety CE LVD (230V)
EMC (EMS / EMI) IEC 61000-4,  CISPR 22 (230V)
Warranty policy Warranty policy may vary depends on region
 