| SMART KING PRO 1000A / 1250A / 1500A / 2000A / 3000A | |
| Ultra small UPS with pure sine wave output for quality protection for computers and servers. Features :
|
|
| MODEL | SKP-1000A |
SKP-1250A |
SKP-1500A |
SKP-2000A |
SKP-3000A |
|
| CAPACITY | Capacity | 600W |
750W |
900W |
1200W |
1800W |
| OUTPUT | Voltage (on battery) | Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning | ||||
| Frequency (on battery) | 50 or 60 Hz +/-0.5% | |||||
| Voltage Regulation( AVR) | AVR automatically
increase output voltage 15% above input voltage if
-9% to -25% of nominal. AVR automatically decrease output voltage 13% below input voltage if +9% to +25% of nominal. |
|||||
| INPUT | Voltage | +/-25% at line input, single phase | ||||
| Frequency | 50 or 60 Hz +/- 5Hz (auto sensing) | |||||
| PROTECTION & FILTERING |
Spike Protection | 420 Joules (2x0V) / 225 Joules (1x0V), 8/20µs | ||||
| Unit Input | Fuse for 2x0V models | |||||
| Overload Protection | UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds | |||||
| EMI/RFI filter | 10dB at 0.15MHz, 50 dB at 30MHz | |||||
| Transfer Time | 6-8 milliseconds (typical), including detection time | |||||
| Short Circuit | UPS output cut off immediately or input fuse protection | |||||
| BATTERY | Type | Hot swappable, sealed, maintenance-free lead acid battery | ||||
| Typical Recharge Time | 4 hours (to 90% of full capacity) | |||||
| Back-up Time (one PC with a 15" LCD monitor) |
about 50 minutes |
about 55 minutes |
about 60 minutes |
about 70 minutes |
about 135 minutes |
|
| Protection | Automatic self-test & discharge protection, Replace battery indicator | |||||
| PHYSICAL | NET WEIGHT kg (lbs) | 15.9 (35.0 lbs) |
16.1 (35.4 lbs) |
16.3 (35.8 lbs) |
16.4 (36.1 lbs) |
19.5 (43.0 lbs) |
| Dimension WxDxH (mm) | 135
x 360 x 170 (5.3" x 14.2" x 6.7") |
170 x 450 x 226 (6.7"x17.7"x8.9") |
||||
| ALARM | Battery Back-up | Slow beeping sound (about 0.25 Hz) | ||||
| Battery Low | Rapid beeping sound (about 1.00 Hz) | |||||
| Overload | Continuously beeping sound | |||||
| INTERFACE | Dry contact | Sends AC fail and battery low signals, and receives shutdown signal from computer. | ||||
| RS232 & USB | Detect battery low, Schedule UPS on/off, AC input/output power status display. | |||||
| SNMP (option) | Simple network management protocol | |||||
| ENVIRONMENT | Ambient Operation | 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-48 deg | ||||
| Audible Noise | <45 dBA (1 meter from surface) | |||||
| Storage Condition | 15,000 meter max. elevation | |||||