Chinese Website
   
   
Home > Product > Off-Line UPS > TUR-500A(AP) / 600A(AP) / 800A(AP) / 1000A(AP)

TURBO SERIES 500A(AP) / 600A(AP) / 800A(AP) / 1000A(AP)
 

Compat design & high performance power protection for workstations, PCs & small electronic equipments.

Features :

  • Fully digitized microprocessor controlled
  • Energy saving (UPS sleep mode)
  • 50/60Hz frequency auto sensing
  • Cold start (DC power on)
  • Buzzer can be muted by pressing on/off button
  • Short circuit and overload protection
  • Single PCB with reliable design
  • Advanced battery management (ABM)
  • Automatic diagnostics & battery chck
  • EMI/RFI noise filter
  • Back up, on-line, battery status, power status display by software*
  • History record of power failure events*
  • Schedule shutdown & reboot*
  • Smart Communication port *

    * AP model only

MODEL   TUR-500A/AP TUR-600A/AP TUR-800A/AP TUR-1000A/AP
ONPUT Capacity 500VA 600VA 800VA 1000VA
No. of sockets

Style A UPS x 2,
Bypass x 1
(Please refer the "output receptacle options")

Voltage (on battery) 500A & 600A model with only 220~240V
Simulated sine wave at 100V / 220V / 240V +/- 5% --- AVE control with PWM
Frequency (on battery) 50 or 60Hz +/- 1Hz
Transfer Time 2-4 milliseconds (Typical)
INPUT Voltage
(single phase)
100V / 110V +/-20%, 120V -20%, +15%
220V / 230V / 240V, 166V ~ 280V at line input
Frequency 50 or 60Hz +/- 10% (auto sensing)
PROTECTION Unit Input Fuse for overload & short circuit protection
Overload Protection UPS automatic shutdown if overload exceeds
110% at 10 seconds, 130% at 3 seconds
Short Circuit UPS output cut off immediately
Spike Protction 460 Joules, (8/20µs)
BATTERY Type Sealed, maintenance-free lead acid batteries
Typical Recharge Time (to 90% of full capacity) 6 Hours
Back-up Time
(a PC with 17" monitor)
4 - 8 mins 6 - 10 mins 30 - 34 mins 32 - 36 mins
Protection Automatic self-test, Over discharge protection, short circuit protection by fuse
PHYSICAL Net Weight kg (lbs) 2.8 (6.2) 3.0 (6.6) 3.7 (8.1) 3.8 (8.4)
Dimension WxDxH (mm) 90 x 254 x 126 (3.5" x 10" x 5") 97 x 254 x 145 (3.8" x 10" x 5.7")
INTERFACE Optional USB port
(AP model only)
Detct battery low, Schedule UPS ON/OFF, AC input/output power status display
ALARM Battery Back-up Slow beeping sound every 4 seconds
(buzzer can be muted by pressing "ON/OFF" butoon)
Battery Low Rapid beeping sound every second
Overload Continue beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max. elevation, 0-95% humidity (No-condensing water), 0-40 deg
Audible Noise < 40dBA (1 meter from surface)