Chinese Website
   
   
Home > Product > Interactive UPS > King 600/1000/1200AP RM

KING 600/1000/1200AP RM
 

Complete protection for internet computers and advanced servers.

Features :

  • Line interactive design
  • Fully digitized microprocessor controlled
  • Tel/modem internet surge suppression
  • Boost and buck AVR
  • EMI/RFI noise filter
  • Surge protection output for critical load
  • On-line, back up, battery fauel status LED
  • Lightning and surge protection
  • Short circuit and overload protection
  • 50/60Hz frequency auto sensing
  • Advanced battery management (ABM)
  • Energy saving (UPS sleep mode)
  • Smart RS-232 communication port
  • AVR boost & buck LED *
  • Cold start (DC power on)
  • Automatically charging when UPS off
  • History record of power failure events
  • Schedule shutdown & reboot
  • Back up, on-line, battery status, power status display by software
  • Hot swappable battery by users *

    * features available on 1200VA and up models

MODEL   KIN-600AP RM KIN-1000AP RM KIN-1200AP RM
INPUT Capacity
(On Battery)
600AV 1000AV 1200AV
Capacity (Surge Protection outlets) 500VA 500VA 500VA
Voltage +/-25% at line input
Frequency 50 or 60 Hz +/-10% (auto sensing)
OUTPUT Voltage (on battery) Simulated sine wave at
100V or 110V/115V/120V or 220V/230V/240V +/-5%
Frequency (on battery) 50 or 60 Hz +/-0.5%
Voltage Regulation (AVR) AVR automatically increase output voltage 15%
above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 13% below input voltage
if +9% to +25% of nominal
Transfer Time 2/4 milliseconds, including detection time
PROTECTION
& FILTERING
Spike Protection 320 Joules
EMI/RFI Filter 10dB at 0.15MHz, 50dB at 30MHz
Unit Input For overload & Short circuit protection
Overload Protection UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
10 Base-T Cable Port Network (UTP, RJ-45) compatible jacks
Short Circuit UPS output cut off immediately or input circuit breaker protection
BATTERY Type Sealed, Maintenancd-free lead acid
Typical Recharge Time 8 hours (to 90% of full capacity)
Back-up Time
(a PC with 15" monitor)
30 - 40 mins 50 - 60 mins 60 - 70 mins
Protection Automatic self-test, Discharge protection, Replace battery indicator
PHYSICAL Net Weight Kg(lbs) 9.2 (20.2 lb) 10.5 (23.1 lb) 15.5 (34.1 lb)
10.4 (22.9 lb) 11.7 (25.7 lb) 18.0 (39.6 lb)
Dimension WxDxH (mm) 483 x 362 x 44 (1U) 483 x 357 x 84 (2U)
INTERFACE RS232 RS-232C Bi-directional communication port
ALARM Battery Back-up Slow beeping sound (about 0.47 Hz)
Battery Low Rapid beeping sound (about 1.824 Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 ¢J
Audible Noise <40dBA (1 meter from surface)
Storage Condition 15,000 meter max


BACK