| Smart King 1500/2000/2500 (A/LCD/RM) | |
| Pure sine wave output for any critical load Features :
|
|
| Tower Model (LED display) | SMK-1500A | SMK-2000A | SMK-2500A | |
| Tower Model (LCD display) | SMK-1500A-LCD | SMK-2000A-LCD | SMK-2500A-LCD | |
| 19" Rack-mount Model | SMK-1500A-RM | SMK-2000A-RM | SMK-2500A-RM | |
| INPUT | Capacity | 1500VA | 2000VA | 2500VA |
| Voltage | +/-25% at line input, single phase | |||
| Frequency | 50 or 60Hz +/-5Hz (auto sensing) | |||
| OUTPUT | Voltage (on battery) |
Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning | ||
| Frequency (on battery) |
50 or 60Hz +/-0.5% | |||
| Voltage Regulation(AVR) | AVR automatically
increase output voltage 15% above input voltage if
-9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal |
|||
| PROTECTION & FILTERING |
Spike Protection | 320 Joules, 2ms | ||
| Unit Input | Fuse for 110V models Except 3000A, breaker for 220V models Except 1000A | |||
| EMI/RFI filter | 10dB at 0.15MHz, 50 dB at 30MHz | |||
| Overload Protection | UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds. | |||
| Transfer Time | 2/4 milliseconds (typical), including detection time | |||
| Short Circuit | UPS output cut off immediately or input fuse(or breaker) protection | |||
| BATTERY | Type | Hot swappable, sealed, maintenance-free lead acid, with 3-6 years lifetime | ||
| Typical Recharge Time | 4 hours (to 90% of full capacity) | |||
| Protection | Automatic self-test & discharge protection, Replace battery indicator | |||
| Back up Time (one PC and one 15" monitor) |
¡Ü 90 min | ¡Ü 120 min | ¡Ü 140 min | |
| Net Weight Kg (lbs) |
Tower | 25.0 (55.0 lb) | 30.0 (66.0 lb) | 30.0 (66.0 lb) |
| 19" Rack-mount | 26.1 (57.4 lb) | 28.4 (62.5 lb) | 28.4 (62.5 lb) | |
| DIMENSION W x D x H (mm) |
Tower | 170 x 450 x 226 (6.7" x 17.7" x 8.9") | ||
| 19" Rack-mount | 483 x 381 x 130 (19.0" x 15.0" x 5.1") | |||
| LCD Indicators | Status | Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault statuts, load | ||
| INTERFACE | RS232 | Detect battery low, Schedule UPS on/off, AC input/output power status display. | ||
| Dry contact | Sends AC fail and battery low signals, and receives shutdown signal from computer. | |||
| Option | Novell, SNMP, Windows NT, Windows 95/98/2000/ME | |||
| ALARM | Battery Back-up | Slow beeping sound (about 0.25Hz) | ||
| Battery Low | Rapid beeping sound (about 1.00Hz) | |||
| Overload | Continuously beeping sound | |||
| ENVIRONMENT | Ambient Operation | 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg | ||
| Audible Noise | <45dBA (1 meter from surface) | |||
| Storage Condition | 15,000 meter max. elevation | |||