Chinese Website
   
   
Home > Product > Interactive UPS > Smart King XL Series 5100

Smart King XL Series 5100
 





UPS with continuous rated capacity for continous backup main unit excludes internal batteries.

Features :

  • Designed for a combination of both rack mount style and tower style
  • True sinewave output
  • Backup time depends on quantities of connected ext. battery packs
  • Built in fast charger (nominal : 5.5A, 3.5A~8A adjustable)
  • Line interactive design
  • Boost and buck AVR
  • Hot swappable battery by users
  • Fully digitized microprocessor controlled
  • Smart RS-232 communication port
  • Lightning and surge protection
  • Short circuit and overload protection
  • 50/60Hz frequency auto sensing
  • Tel/modem internet spike protection
  • Smart power management with software
  • Cold start (DC power on)
  • Overload, on-line, battery status LED or LCD display
  • Load/Battery power meter display
  • Advanced battery management (ABM)
  • Energy saving (UPS sleep mode)
  • SNMP capability

Tower Model SXL-5100A
19" Rack-mount Model SXL-5100A-RM (5U)
INPUT Capacity 5100VA
Voltage +/-25% at line input, single phase
Frequency 50 or 60Hz +/-5Hz (auto sensing)
OUTPUT Voltage
(on battery)
Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
Frequency
(on battery)
50 or 60Hz +/-0.5%
Voltage Regulation(AVR) AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal
PROTECTION
& FILTERING
Spike Protection 660 Joules (@10/1000µs)
Unit Input Fuse for 110V models except 3000A, breaker for 3000A and 220V models
EMI/RFI filter 10dB at 0.15MHz, 50 dB at 30MHz
Overload Protection UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
Transfer Time 2/4 milliseconds (typical), including detection time
Short Circuit UPS output cut off immediately or input fuse(or breaker) protection
BATTERY Type Hot swappable, sealed, maintenance-free lead acid (12V/17AH)
Typical Recharge Time 4 hours (to 90% of full capacity)
Protection Automatic self-test & discharge protection, Replace battery indicator
Battery Quantity 6 pcs
Built in fast charger Nominal : 5.5A, 3.5A~8A adjustable
Back Up Time Tower Model Full Load 9.5 ~10.5 mins
Half Load 25 ~ 26 mins
19" RM Model Full Load 9.5 ~10.5 mins
Half Load 25 ~ 26 mins
Net Weight Kg
(lbs)
Tower Model 81.8 (179.9 lbs)
19" Rack-mount 81.8 (179.9 lbs)
DIMENSION
W x D x H (mm)
Tower 710 x 214 x 428 (27.9" x 8.4" x 16.8")
19" Rack-mount 483 x 710 x 214 (19" x 27.9" x 8.4")
INTERFACE RS232 Detect battery low, Schedule UPS on/off, AC input/output power status display.
Dry contact Sends AC fail and battery low signals, and receives shutdown signal from computer.
Option Novell, SNMP, Windows NT, Windows 95/98/2000/ME
ALARM Battery Back-up Slow beeping sound (about 0.25Hz)
Battery Low Rapid beeping sound (about 1.00Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg
Audible Noise < 45 dBA (1 meter from surface)
Storage Condition 15,000 meter max. elevation


BACK



Copyright © Powercom Co., Inc. 2006, All Rights Reserved.