ELECTRICAL CHARACTERSTICS:

Maximum Power (Pmax) 175W
Voltage @ Pmax (Vpm) 23.7V
Current @ Pmax (lpm) 7.38A
Open circuit voltage (Voc) 28.9V
Short circuit current (Isc) 7.86A
Output tolerance +/-3%
Maximum system voltage 1000Vdc
Series fuse rating 10A
Application DC 24V system
System Cell 6" Multicrystalline sillicon
No. of cells and connections 48 pcs in series (6 x 8)
Efficiency of module 13.4%
Temperature coefficient of Pmax -0.38%/°C
Temperature coefficient of Voc -0.32%/°C
Temperature coefficient of Isc +0.08%/°C

* measured at STC (Standard Test Condition; 1000W/M2 irradiance, AM 1.5G and 25°C)

ABSOLUTE MAXIMUM RATINGS
Operating temperature -40 to +90°C
Storage temperature -40 to +90°C


Quality Assurance

1. Electrical insulation test.
2. Outdoor exposure test
3. Hot-spot endurance test.
4. UV-exposure according IEC 61345
5. Thermal cycling.
6. Humidity freezze.
7. Damp heat test.

8. Robustness of terminations test.

9. Wet leakage current test.
10. Mechanical load test.
11. Hail impact test.
12. Bypass diode thermal test.
MECHANICAL CHARACTERISTICS
Dimension (WxLxH) 1316 x 995x 50 mm
Weight Approxmatelly 16.87Kg
Packing configuration Horizontal
Size of carton 1373 × 1071 × 955mm
Pallet quantity 18 pcs/pallet
Loading capacity (20ft. container) 16 pallet/container
Loading capacity (40 ft. container) 32 pallet/container
Construction Front: high transmission low-iron tempered glass, 3.2mm
Back: PVF/PET/PVF
Encapsulates: EVA
Junction box IP65, weatherproof
Bypass diodes 2 diodes to avoid power decreasing by shade
Output cable 4mm2 cable with polarized weatherproof connectors Negative 900mm, Positive 900mm
Frame Clear anodized aluminum, AL6063-T5

I-V CURVES

QUALITY
ISO 9001:2000 certified
IEC 61215 and IEC61730 are certified by TÜV
Warranty: 10 years limited warranty of 90% power output and 25 years limited warranty of 80% power output

INSTALL AND SAFETY GUIDE
DO NOT damage or scratch the rear surface of the module
DO NOT handle or install modules when they are wet.
ONLY qualified personnel should install or perform maintenance.
BE AWARE of dangerous high DC voltage.