Chinese Website
   
   
Home > Product > Solar Cell > PPV-272S6

PPV-272S6 272Wp Monocrystalline silicon phtovoltaic module
 

ELECTRICAL CHARACTERSTICS:

Maximum Power (Pmax) 272W
Voltage @ Pmax (Vpm) 35.9V
Current @ Pmax (lpm) 7.57A
Open circuit voltage (Voc) 43.97V
Short circuit current (Isc) 8.15A
Output tolerance +/-3%
Maximum system voltage 1000Vdc
Series fuse rating 10A
Application DC 24V system
System Cell 6" Monocrystalline sillicon
No. of cells and connections 72 pcs in series (6 x 12)
Efficiency of module 14%
Temperature coefficient of Pmax -0.37%/°C
Temperature coefficient of Voc -0.34%/°C
Temperature coefficient of Isc +0.09%/°C

* measured at STC (Standard Test Condition; 1000W/M2 irradiance, AM 1.5G and 25°C)

ABSOLUTE MAXIMUM RATINGS
Operating temperature -40 to +90°C
Storage temperature -40 to +90°C


Quality Assurance

1. Electrical insulation test.
2. Outdoor exposure test
3. Hot-spot endurance test.
4. UV-exposure according IEC 61345
5. Thermal cycling.
6. Humidity freezze.
7. Damp heat test.

8. Robustness of terminations test.

9. Wet leakage current test.
10. Mechanical load test.
11. Hail impact test.
12. Bypass diode thermal test.
MECHANICAL CHARACTERISTICS
Dimension (WxLxH) 1947 x 993 x 50 mm
Weight Approxmatelly 23.99Kg
Packing configuration Horizontal
Size of carton 2005 × 1071 × 955mm
Pallet quantity 18 pcs/pallet
Loading capacity (20ft. container) 10 pallet/container
Loading capacity (40 ft. container) 22 pallet/container
Construction Front: high transmission low-iron tempered glass, 3.2mm
Back: PVF/PET/PVF
Encapsulates: EVA
Junction box IP65, weatherproof
Bypass diodes 2 diodes to avoid power decreasing by shade
Output cable 4mm2 cable with polarized weatherproof connectors Negative 900mm, Positive 900mm
Frame Clear anodized aluminum, AL6063-T5

I-V CURVES

QUALITY
ISO 9001:2000 certified
IEC 61215 and Safety Class II standards are in progress by TÜV
Warranty: 10 years limited warranty of 90% power output and 25 years limited warranty of 80% power output

INSTALL AND SAFETY GUIDE
DO NOT damage or scratch the rear surface of the module
DO NOT handle or install modules when they are wet.
ONLY qualified personnel should install or perform maintenance.
BE AWARE of dangerous high DC voltage.


MODULE DIMENSIONS

** This document summarizes product specifications which are subject to change without prior notice.

BACK




Copyright © Powercom Co., Inc. 2006, All Rights Reserved.