| SOLAR KING | |
| The most advanced grid-tie PV inverter in the world. Converting sun light into electricity energy for home / industrial applications, and powering up our world with free solar energy is now no longer just a dream. Features : Powercom Solar king is the most advanced solar
inverter for grid connected PV-plant. Solar king
is designed base on the following principles: With 3 different input voltage ranges allowing customer to have flexible choice for different applications. 96.5% high converting efficiency and up to 99% high MPPT efficiency are both above average market standard. Solar King is designed to be user friendly and with easy installation to reduce installation costs. User can easily monitor the system status from the remote control display LCD panel. IP-65 enclosure protects against severe outdoor installation environment. USB & RS-232 communication ports are available for remote monitoring & control. With optional RS485 or SNMP card for future expansion. |
|
| Model | SLK-1500 | SLK-2000 | SLK-3000 | SLK-4000 |
| Input Data | ||||
| Maximum Input Power | 1875W | 2500W | 3750W | 5000W |
| Nominal DC Voltage | 360V~400V | |||
| Maximum input voltage | 500VDC | |||
| MPPT voltage range | 150V to 500V +/-5% |
|||
| System start-up voltage | 100 +/-5% | |||
| Working voltage range * | 100 +/-5% ~ 500-5%+0%V | |||
| Initial feeding voltage * | 150V +/-5% | |||
| Full rating working range | 250V to 500V | |||
| Max. input current | 7.5ADC | 10ADC | 15.2ADC | 20ADC |
| Shutdown voltage | 80V typical | |||
| DC voltage ripple | < 10% | |||
| DC insulation resistance ** | > 8M ohm | |||
| DC Switch | On/Off 20A | |||
| DC Connector | Tyco-contract (1-pair) | |||
| Attachd DC Connector | Tyco-contract (1-pair) cable type | Tyco-Contract (3 pairs) |
||
| Output data | ||||
| Nominal output power | 1500W | 2000W | 3000W | 4000W |
| Maximum output power (The time is limited to 10 minutes @ 50°C ambient) |
1650W | 2200W | 3300W | 4400W |
| Operational Voltage range *** | 198V, minimum 256V maximum |
|||
| Operational Normal voltage | 230 Vac | |||
| Operational frequency range | 50/60Hz, auto
selection |
|||
| Nominal output current | 6.6A | 8.7A | 12.1A | 17.4A |
| O/P current distortion | THD<5%, each harmonics <3% | |||
| Power Factor | > 0.99% | |||
| DC current injection | <0.5% of rated inverter output current | |||
| General Data | ||||
| Internal power consumption | < 7W | |||
| Standby power (at night) | < 0.1W | |||
| Minimum conversion efficiency (DC/AC) | >90% Under input voltage>210V, load >20% |
|||
| Maximum Conversion Efficiency (DC/AC) | >94% | >95% | >96% | |
| European Efficiency | >93% | >94% | >95% | |
| GFCI threshold | See ground fault current detection | |||
Ground current detection range |
0~500mA | |||
| Ground current detection frequency | 0~700Hz | |||
| DC input impedance requirement | >2M Omega | |||
| Protection degree | IP 65 or IP43 | |||
| Operation temperature | -25 to 50°C | |||
| Humidity | 0 to 95%, non-condensing | |||
| Heat Dissipation | Convection | |||
| Acoustic noise level | <40dB, A-weighted, frequency up to 20kHz | |||
| Altitude | Up to 3000m without power derating, 5°C derated for each additional 500m | |||
* Load curve :

The relation of input DC voltage and output power is shown
in figure. Once input V is less than 250V, the relation
of I/P V and load % is : Load% =
0.4 x Vi
1. This is voltage range that inverter will start to feed
power to grid.
2. The DC resistance requirement for positive or negative
terminal to chasis ground
3. In VDE0126-1-1, it is ¡V20%/ +15%. DK5940, RD1663 are
also available.
4. Based on the limit of VDE0126-1-1
5. Based on limit of IEEE929
6. Under the output voltage is 230VAC
7. Under utility voltage THD<3%
8. under input voltage>= 400V, full rated output power,
25oC ambient
9. According to VDE0126-1-1 requirement
Mechanical Requirements:
| Model | SLK-1500 | SLK-2000 | SLK-3000 | SLK-4000 |
| Physical: W*D*H (mm) | 352*300*133 |
352*300*133 |
352*300*133 | 550*300*133 |
| Physical: Weight (kg) |
14 | 14 | 14 | 21 |
| Shipping: W*D*H (mm) |
465*465*285 |
465*465*285 | 465x465x285 | 665*465*285 |
| Shipping: Weight (kg) |
16 | 16 | 16 | 23 |
** The dimension and weight here could be changed due
to product modification